With around 250 locations and 90 serve centers, we are represented in the most important economic regions of the world. The advantages are clear: short paths to our customers, fast response times and a shared language.
If a STD is employed, it is possible to change seals with the vessel loaded and under pressure (shaft must be stationary!). Installation dimensions according to DIN 28138 Part 1 are possible. Material properties have to be taken into account.
Advantages
Can be installed in each position.
Operating range
Shaft diameter: d3 = 40 ... 200 mm (1.57" ... 7.87")
Pressure: p1 = 16 bar (232 PSI)
Temperature: t = +100 °C (+212 °F)
Elastomer sealing element (Item no. 1) with pneumatic or hydraulic actuation
(closing pressure p4 > p1).
! It should be noted that the extremal values of each
operating parameter cannot be applied at the same time
because of their interaction.
Standards and approvals
Compliant to TA Luft (German Clean Air Act)*
(*) Shut-down seals are not specifically mentioned in the
TA Luft but may be a solution in certain applications. Their use must be verirfied with the approval authorities.
Recommended applications
Chemical industry
Pharmaceutical industry
Agitators
Notes
This seal can only be used if the product does not harden or congeal during the shut down period or for sterile operation (fermenting vessels). Not available in PTFE.